Type : Bubble
Product : Aluminium Foil
Colour : Aluminium
Size : 1.20M(W) X 40M(L) (Bubble Diameter 10MM Thickness 4MM)
Weight : ± 10.80kg
Packing : 1 Roll
Min Order Per : 1 Roll
Product Description
SUN-FOIL® SB200-FR is used as insulation against radiant heat transfer and can be used to its greatest advantage in instances where radiation is the predominant means of heat transfer.
SUN-FOIL® SB200-FR is an excellent reflector of all long wave radiant heat that strikes it – SINGLE SIDED REFLECTIVE OF UP TO 98% of all radiant heat.
Fire Attributes
SUN-FOIL® SB200-FR is classified as Class “O” in accordance to fire tests on building material and structures.
- Bristish Standard, BS 476-6 : Fire Propagation Test
- Bristish Standard, BS 476-7 : Surface Spread Of Flame Test
Thermal Properties
SUN-FOIL® SB200-FR is tested in accordance to MS 2095, ISO 8301 / MS ISO 8302 for thermal resistance, R-value 1.239 m²K/w
Awards & Certificates
- Malaysia Standard – MS 2095, SIRIM QAS International Sdn, Bhd.
- ISO 9001: 2015, Guardian Independent Certification
- Jabatan Bomba dan Penyelamat Malaysia
- CIDB Malaysia
- Malaysia Green Building Confederation (MGBC)
- Asian Reflective Foil Association (ARFA)
Bubble FOIL (Fire Retardant)
SUN-FOIL® SB200-FR is made by single sided high reflectivity pure aluminium bonded with a layer of 10mm FR polyethylene bubble sheet with a single sided high quality reflective aluminium film by special FR bonding material. It provides excellent insulation properties and effective radiant barrier.
SUN-FOIL® SB200-FR is designed light-weight. It is easy to install as it does not require mesh due to high tensile strength and edge tear resistance.
SUN-FOIL® SB200-FR is also flame retardant, waterproof, non-toxic, bacteria free, fungus and corrosion resistant.
TECHNICAL DATA
Description | Test Method | Unit | Value | ||||||||
Grammage | In House | g/m² | 200 ± 10 | ||||||||
Thickness | In House | μ m | 4 ± 0.2 | ||||||||
Tensile Strength | In House | N/50mm | MD ≥ 200 ± 50 | ||||||||
CD ≥ 200 ± 50 | |||||||||||
Elongation | In House | % | MD ≥ 80 | ||||||||
CD ≥ 30 |
Technical Information provided represent average result of test conducted under standard procedure and is subject to variation.
No guarantee can be made regarding specific applications or patent rights.
FIRE RETARDANT TEST FOR SB200-FR
Characteristic | Test Method | Specification | |||||||
Fire Propagation of Material |
BS 476 ; Part 6 |
< 6 | |||||||
Sub-Index, i₁, i₂, i₃ | < 12 | ||||||||
Overall Performance Index | (Sirim Report 2018FE0657) | ||||||||
Surface Flame Spread Test | BS 476 ; Part 7 | Class 1 | |||||||
(Sirim Report 2019FE0656) | |||||||||
Classification of Fire Hazard | Class O |